Communication Alarms
| Code | Severity | Message | Cause & Action |
|---|---|---|---|
COMM-001 |
Critical | PLC Connection Lost | Network failure or PLC offline. Check network cable, PLC power, and IP settings. |
COMM-002 |
High | QCS Connection Timeout | Scanner data not received. Verify QCS network and DIU connection. |
COMM-003 |
Medium | Communication Slow | Response time exceeds threshold. Check network load and switch capacity. |
COMM-004 |
High | Modbus Read Error | Register read failed. Verify slave ID and register addresses. |
COMM-005 |
High | Modbus Write Error | Register write failed. Check PLC write permissions. |
COMM-006 |
Medium | Reconnection Attempt | System attempting to reconnect. Monitor for success. |
Actuator Alarms
| Code | Severity | Message | Cause & Action |
|---|---|---|---|
ACT-001 |
High | Valve Not Responding | Zone {N} not tracking setpoint. Check valve connection and air supply. |
ACT-002 |
Medium | Position Limit Reached | Zone {N} at operating limit. May indicate profile issue or limit too restrictive. |
ACT-003 |
Medium | Feedback Deviation | Zone {N} feedback differs from setpoint. Possible valve or sensor issue. |
ACT-004 |
Low | Zone In Manual Mode | Zone {N} not under automatic control. Intentional or needs attention. |
ACT-005 |
High | Valve Stuck | Zone {N} not moving despite commands. Perform valve flush or manual check. |
ACT-006 |
Medium | Bending Limit Exceeded | Zone {N} position limited by neighbor. Normal constraint behavior. |
Profile Alarms
| Code | Severity | Message | Cause & Action |
|---|---|---|---|
PROF-001 |
High | Invalid Profile Data | Scanner data out of range or corrupt. Check QCS sensor calibration. |
PROF-002 |
Medium | Edge Detection Failed | Cannot determine web edges. Verify profile and edge threshold settings. |
PROF-003 |
Medium | Profile Stale | No new profile data received. Check scanner operation and communication. |
PROF-004 |
Low | Spike Detected | Outlier removed from profile. May indicate sensor or process issue. |
PROF-005 |
Medium | Profile Width Changed | Detected web width change. Verify sheet width and edge detection. |
Control Alarms
| Code | Severity | Message | Cause & Action |
|---|---|---|---|
CTRL-001 |
High | 2-Sigma High | Profile variation exceeds threshold. Check control parameters and valve operation. |
CTRL-002 |
Medium | Control Disabled | Automatic control not active. Check mode and enable conditions. |
CTRL-003 |
Medium | Control Oscillating | Detected oscillation pattern. Reduce control gain. |
CTRL-004 |
Low | Target Changed | Target profile or basis weight changed. Informational. |
CTRL-005 |
Medium | Control Timeout | Control cycle exceeded time limit. Check system performance. |
System Alarms
| Code | Severity | Message | Cause & Action |
|---|---|---|---|
SYS-001 |
High | License Expiring | License expires in {N} days. Contact PowerFlow for renewal. |
SYS-002 |
Critical | License Expired | License no longer valid. Control disabled until renewed. |
SYS-003 |
Medium | Disk Space Low | Log storage space limited. Archive or delete old logs. |
SYS-004 |
Low | Configuration Saved | System configuration saved. Informational. |
SYS-005 |
Medium | Database Error | Data storage issue. Check disk and database integrity. |
SYS-006 |
Low | Application Started | System startup completed. Informational. |
Need Help?
For persistent alarms that cannot be resolved, contact PowerFlow Technical Support with the alarm code and any relevant system logs.